Chapter 2, Section 15

AM Tower Guy Wires, Guy Insulators and Anchors: What Holds the Tower Up

Part of AM Radio Facts and Trivia: The AM Broadcast Band in the USA. Updated November 21, 2026.

A guyed AM tower is a tall, thin steel mast that would fall over on its own. Steel cables called guy wires, or guys, hold it up, pulling from three sides down to blocks of concrete buried in the ground. On an AM tower the guys have an extra job: they must stay out of the way of the signal. This page follows a guy from the tower down to the anchor: what it is made of, how tight it is, why it is broken up by porcelain, how it is joined at each end, and how AM stations have lost towers when something went wrong.

This page goes with AM Tower Base Insulators (Chapter 2, Section 14), which covers the porcelain under the tower.

How a Guyed Tower Is Laid Out

Guys normally run in three directions, 120 degrees apart, with a turnbuckle at the bottom of each one. Taller towers have more guy levels; two to five is common, and an engineering handbook puts about ten as the practical limit, with no more than five tied to one anchor. The anchor distance, from the tower base out to the anchor, is often about 80 percent of the tower’s height. That figure is a rule of thumb from tower makers, not a standard. At 80 percent, a guy from the top of the tower meets the ground at about 51 degrees.

A GUYED AM TOWER, ONE SIDE OF THREEburied blockbase insulatorguy bracket ortorque armporcelain insulators breakeach guy into short piecesequalizer plateanchor shaftanchor distance: often about 80 percent of tower height (rule of thumb)Guys run in three directions, 120 degrees apart. This shows one direction. Not to scale.

Drawing 2.15-1

The 1930s Blaw-Knox diamond towers needed only one guy level, at their wide middle. At WSM in Nashville, eight guy cables attach at the waist, about 680 feet up, and each one is pulled to 55,000 pounds, according to the station’s chief engineer.

What the Guys Are Made Of

The standard American guy is galvanized steel strand: steel wires twisted together and coated with zinc against rust, made to the ASTM A475 standard. Towers use its strongest grade, Extra High Strength, written EHS. Sizes up to 9/16 inch have 7 wires; 5/8 inch and larger have 19. “Breaks at” is the pull at which new strand snaps.

Size (inches)WiresWeight, pounds per 1,000 feetBreaks at (pounds)
1/471216,650
5/16720511,200
3/8727315,400
7/16739920,800
1/2751726,900 (one source says 26,400)
9/16767135,000 (one source says 34,500)
5/81979640,200
3/4191,15558,300
7/8191,58179,700
1192,073104,500

Table 2.15-2

The table is from one strand maker, with most sizes matched by one to three other sellers. For the 1/2 and 9/16 inch sizes, sources differ by about 2 percent, as shown.

The non-metal choice. Some AM stations use guys made of aramid fiber rope (the Kevlar family), sold as Phillystran. It does not carry electricity, so it needs no break-up insulators, and it weighs about a third as much as steel of the same strength. WWRL in Secaucus, New Jersey, first guyed its towers with it in 1970; when the old lines were finally replaced, tests found no loss of strength after about 40 years. One online comment claims fiber guys need replacing every 6 to 10 years, which does not fit the WWRL result.

How Tight They Are Pulled

A new guy is usually pulled to about 10 percent of its breaking strength; three sources agree. The current tower standard is reported to allow 7 to 15 percent, but that comes from an engineers’ forum, not from the standard’s own text, which is sold only to subscribers. An AM engineering newsletter says a guy on a 200 foot tower typically carries 1,000 to 1,500 pounds, and warns that uneven guys can crook, twist or even topple a tower. Guys stretch over time and change with the temperature, so tower crews check them with a pull gauge or by timing a wave sent up the wire. Tugging on a guy by hand tells very little.

Steady breezes of about 2 to 30 mph can make guys hum and shake, which slowly loosens hardware. Small dumbbell-shaped weights called Stockbridge dampers, clamped on in pairs, calm the shaking.

Why AM Guys Are Broken Into Pieces

On an AM station the whole tower is the antenna. A steel guy hundreds of feet long, tied to the top of that antenna, can pick up the signal and send it back out like a second antenna, bending the station’s coverage pattern. So AM guys are cut into short pieces by porcelain guy insulators, spaced no more than about one tenth of a wavelength apart (some sources say one eighth to one tenth; four sources agree on the rule). The pieces are too short to pick up much signal. The lower the frequency, the longer the wave, so low-frequency stations can space their insulators farther apart. The station’s consulting engineer sets the exact spacing.

Largest usual space between guy insulators (one tenth of a wavelength)050100150200540 kHz182 ft700 kHz141 ft900 kHz109 ft1100 kHz89 ft1300 kHz76 ft1500 kHz66 ft1700 kHz58 ftFeet (worked out on this site from the frequency)

Drawing 2.15-3

Even broken-up guys still re-radiate a little. A 1980 patent by the antenna designer Andrew Alford said that on very tall towers in a directional array, guys can cause a large share of the unwanted re-radiation, and that one guy set near 1540 kHz might need about 40 insulators.

The Guy Insulators

Austin Insulators, the last maker of broadcast insulators, describes three kinds:

Austin insulator familySafe working pull (pounds)Breaking pull (pounds)Electrical rating
Egg or Johnny Ball (AOA-35 to AOA-120)11,500 to 40,000about 3 times workingspark-over 20 to 30 kV, dry
Compression break-up (C-018 to C-123)40,000 to 275,000120,000 to 825,000spark-over 25 kV wet; 12 kV RF working limit

Table 2.15-4

Both rows come from one source, the maker. No prices were found. Austin itself says recent failures have raised doubts about the “fail-safe” claim for its compression type.

The insulator next to the tower is special. The whole tower carries the station’s RF voltage, so the first insulator at the tower end of each guy takes the most. Austin says its egg and compression types are not meant for that spot and recommends its oil-filled type there.

How a broken one shows up. The usual first sign is not a falling tower but a small change in the tower’s readings in the transmitter building, with nothing wrong inside. At KLIZ in Brainerd, Minnesota, a 2015 windstorm damaged about a dozen egg insulators and broke at least one clear through, which joined two steel sections of guy. The night pattern’s timing moved about 2 degrees and its current ratios about 3 percent. Engineers check guy insulators with binoculars. As early as 1938, RCA’s George Brown wrote that a spark of static electricity across a guy insulator can start an arc that the station’s own signal keeps alive.

From the Tower to the Ground

A guy is a chain of parts, and every link must hold the full pull:

  1. At the tower: each guy level fastens to the legs with a guy bracket, or with a star-shaped torque arm that also keeps the tower from twisting, joined by shackles (U-shaped links closed with a pin).
  2. Ends of the strand: usually a preformed grip, a set of spiral steel rods that wrap the strand and hold it by friction, rated to hold as much as the strand itself. Wire rope clips and poured sockets are other choices.
  3. Along the guy: the porcelain insulators, each with the guy looped through it.
  4. At the bottom: a turnbuckle, a threaded link that screws shorter or longer to set the tension, with the last insulator just above it. Inspection forms check that each turnbuckle has a safety wire or pin so it cannot unscrew.
  5. At the anchor: several guy levels meet on a thick steel equalizer plate, one hole per guy, on top of the anchor shaft. One maker’s five-hole plate is rated for 64,800 pounds.

The Anchors, and the Rust Nobody Sees

On large towers the usual anchor is a deadman: a big block of steel-reinforced concrete buried in the ground. A galvanized steel anchor shaft runs from the block up through the soil, at the angle of the guys, to the equalizer plate. The block resists the upward pull with its own weight and the soil on top of it. Lighter towers may use giant screw anchors or anchors grouted into rock.

AT THE ANCHOR: WHERE THE GUYS MEET THE GROUNDground surfaceconcrete deadman blockrust zone: shaft in wet soil,between the surface and the blockequalizer plateguys from threetower levelsturnbuckles, safety-wiredso they cannot unscrewlast insulator just abovethe turnbucklecopper ground radial: bonded to the shaft, itcan make a battery that eats the steelNot to scale. Concrete block and shaft sizes vary; no typical size was found.

Drawing 2.15-5

The weak spot is the shaft between the ground surface and the top of the concrete, where bare steel sits in wet soil. Two causes are named. One is galvanic corrosion: copper ground rods or wires bonded to the galvanized shaft make a natural battery, and the steel side is slowly eaten away. The other is stray current, for example from a nearby pipeline’s own anti-rust system, which can enter one anchor and leave through another. The fixes are a concrete collar on the shaft, changing the grounding metal, or a lump of zinc or magnesium buried beside it that corrodes in the steel’s place, at about $500 per anchor in one report.

AM sites may be especially exposed, because every AM tower sits on a buried web of copper radials, often in wet, low ground chosen because it conducts well. That is an inference: no study of AM anchors in particular was found, and no AM tower collapse caused by anchor rust turned up in the record. The anchor-rust collapses that are on record all happened at towers of other kinds of stations.

Inspection. An AM engineering newsletter tells engineers to dig a few inches around each anchor shaft and, if they find rust, to stop and call the tower company. In 2017 the tower climbers’ association (NATE) published an anchor inspection protocol whose second level is “dig to block,” digging all the way down to the concrete. The current tower standard, TIA-222 revision H, in force since January 1, 2018, requires owners to keep a corrosion plan for anchor shafts touching soil and to check them before anyone climbs. A common rule of thumb is to inspect guyed towers at least every three years and after bad storms, but that interval could not be confirmed from the standard itself.

When Guys Go Wrong: AM Stations That Lost Towers

These are the AM stations found with a guy, guy insulator or guy anchor incident. “Reports only” means the facts come from news summaries.

YearStationWhat happenedSources
1974WMMM, Westport, ConnecticutA phone company truck snagged a guy that crossed its parking lot. The west tower came down.1
1977WMMM, Westport, ConnecticutVandals cut a guy. One of the two towers fell.1
2008WBIG 1280, Aurora, IllinoisA medical helicopter hit a guy about 700 feet up the 734 foot tower. Four people died.2
2009WTJV 1490, DeLand, FloridaA truck caught a guy and the 400 foot tower fell.2
about 2009WAEB 790, Allentown, PennsylvaniaVandals cut guys on one tower of a five-tower array. The 350 foot tower fell; the case was still unsolved in 2010.2
2015KLIZ 1380, Brainerd, MinnesotaA windstorm whipped the guys and damaged about a dozen egg insulators. The night pattern shifted slightly. Every guy and insulator on the 380 foot tower was replaced in a week.1
2016KWAL 620, Wallace, IdahoA pickup truck hit a guy and the north tower was pulled into the river. It was never rebuilt.2
2022 to 2023WSJS 600, Winston-Salem, North CarolinaPolice said a tool was used to cut the parts holding the towers to the ground. Three of the four 410 foot towers fell over about three weeks.4, reports only
2024WJLX 1240, Jasper, AlabamaThieves cut the guys and carried off the whole 200 foot tower. There was no insurance; replacing it was put at $60,000 to $100,000.3, reports only
2024KKOB 770, Albuquerque, New MexicoA hot air balloon at the Balloon Fiesta snapped a guy and the tower collapsed. No one was hurt. Reports give its height as 645, 650 or 800 feet.3
2024KRMO 990, Joplin, MissouriA guy snapped, cause not given, and the 1949 tower fell, just missing the building.1
2025WRDT 560, Monroe, MichiganA farm tractor caught an outer guy of tower 4 and the 417 foot tower fell. The station went back on the air from its night site at 125 watts.1

Table 2.15-6

Of the twelve, eight came from the bottom end of a guy, where it is easy to reach: four were snagged by trucks, a tractor or a parking lot visitor, and four were cut by vandals or thieves. After the WRDT loss, the engineer Cris Alexander suggested brightly painted, concrete-filled posts around guy anchors, and a spotter whenever farm machines work near the guys.

Two other AM cases involved guys without starting with them. At KFI 640 in Los Angeles, in December 2004, a small plane hit the 750 foot tower near the top, killing two people, and a whipping guy damaged a roof; the guy anchors were redone during the rebuild. KROS 1340 in Clinton, Iowa, lost its 400 foot tower in the August 2020 derecho, with no guy cause reported.

Sources: Prysmian strand datasheet, 2020, with ROHN dealer 3 Star Inc. and other strand sellers; ASTM A475; The BDR, “Inspecting an AM Tower,” December 2012; Austin Insulators guy insulator pages (egg and compression break-up), retrieved November 2026; Mark Persons, “Lessons of a Major Guy Line Project,” Radio World, March 7, 2017 (KLIZ); Cris Alexander, Radio World, 2011; Radio World repost of the WWRL Phillystran story (KAB, 2021); oldradio.com (WSM tower); US Patents 4,207,575 (Alford, 1980) and 2,231,492 (Brown, filed 1938); PLP Big Grip literature; ROHN torque arm and equalizer plate listings; AFL (Stockbridge dampers); David Davies, SBE, and Radio World on anchor corrosion; OSHA bulletin, June 12, 1991; Wireless Estimator, 2017 (NATE protocol); Inside Towers, 2019 (TIA-222-H sections 14.4 and Annex J); John Battison, Radio World, 2005 (TIA-222-G); CT Radio History (WMMM); Radio World and Flight Safety Foundation (WBIG); Radio World and Wikipedia (WTJV); Fybush.com, 2010 (WAEB); Shoshone News-Press, 2021 (KWAL); Barrett Media and Wireless Estimator, 2023 (WSJS); KSAT/AP, 2024 (WJLX); Wireless Estimator and KOB, 2024 (KKOB); Radio Ink, 2024 (KRMO); Radio World, 2025 (WRDT); oldradio.com and Radio World (KFI); NorthPine, 2020 (KROS). A note on the facts: the TIA-222 tower standard is sold only to subscribers and was not read directly; the 7 to 15 percent tension range and the three-year inspection rule are second-hand. The Austin ratings come from one source, the maker. The KLIZ, WMMM, KRMO and WRDT accounts each rest on one published source; the WSJS and WJLX facts come from news summaries. Distances in Drawing 2.15-3 are worked out on this site from frequency.

© 2026 Chris, N6JET. Free to read and share for non-commercial use with credit (Creative Commons BY-NC 4.0). Not for sale.

More in The Tower and Antenna

All AM radio stories by subject · AM radio interactive tools and simulators · AM Trivia Challenge quiz